Error code: AC Reversed

Cause of error code AC Reversed

The Control System has detected the power supply polarity is reversed

Solution for error code AC Reversed

• Check the 120 VAC wall outlet
  supplying power to the water heater for correct polarity and ground using a     AC volt meter or a plug in tester. 

• Check incoming power supply wiring to the water heater in the junction box -   ensure that the hot wire is connected to the water heater’s black wire and       the neutral wire is connected to the water heater’s white wire inside the         junction box. 

• Check for 120 VAC at CCB’s J3 Socket pins 1 & 3 with J3 plug inserted,         power on.  Check for AC voltage between pin 1 and ground - should indicate   120 VAC. Check for AC voltage between pin 3 and ground - should indicate 0   VAC.