ErrorHelp.us

Heating  Heating

Brand

HTP HTP List all brands

Type:

Elite Fire Tube Combi (floor Mount) view Elite Fire Tube Combi (floor Mount) List all types

Error code:

Er:72
List all errors


Error code: Er:72

Cause of error code Er:72

Flame Signal Detected before Ignition 

Solution for error code Er:72

This Error Code will go away when the condition is remedied. If Error happens again:
1. Check the appliance cover. Ensure it is secure. Flame detection sensor can detect an external light source.
2. Check flame detection sensor. Ensure connections are secure. Normal operating settings are more than 2.5DC before ignition, less than 2.5DC after ignition.
3. If the problem persists, replace the main control.


Share this page: Facebook Twitter