ErrorHelp.us

Heating  Heating

Brand

HTP HTP List all brands

Type:

Elite Fire Tube Combi (floor Mount) view Elite Fire Tube Combi (floor Mount) List all types

Error code:

Er:85
List all errors


Error code: Er:85

Cause of error code Er:85

Freeze Protection (Appliance has detected water temperature below 34o F (1oC) 

Solution for error code Er:85

This Error Code will go away when the freezing condition is remedied. If Error happens again:
1. Ensure appliance is located in a mechanical room protected from freezing conditions.
2. Ensure all valves are open to the appliance, there are no leaks.
3. Check wiring connections to low water level sensor. Ensure all are secure.
4. Check low water level sensor resistance. If resistance is zero, replace the sensor.
5. If the problem persists, replace the main control