ErrorHelp.us

Heating  Heating

Brand

HTP HTP List all brands

Type:

Elite Fire Tube Combi (wall Mount) EFTC-140W view Elite Fire Tube Combi (wall Mount) EFTC-140W List all types

Error code:

Er:40
List all errors


Error code: Er:40

Cause of error code Er:40

Gas Leakage is Detected for Greater than 5 seconds, or three times within 10 minutes

Solution for error code Er:40

IMPORTANT: If you smell gas, STOP! Follow the instructions on page 2, this manual, and call a qualified service technician or the fuel gas utility. 


Press the Power button to clear the Error Code.
If Error happens again:


- Check the appliance cover. Ensure it is secure.
- Check gas connections for leakage with a soapy solution. Fix any leaks.
- Check condition of the burner assembly.
- If the problem persists, replace the main control.


Share this page: Facebook Twitter





© 2025 ErrorHelp.us