ErrorHelp.us

Heating  Heating

Brand

HTP HTP List all brands

Type:

Elite Fire Tube Combi (wall Mount) EFTC-140W view Elite Fire Tube Combi (wall Mount) EFTC-140W List all types

Error code:

Er:94
List all errors


Error code: Er:94

Cause of error code Er:94

Exhaust Sensor detects Vent Temperature is Greater than 190ºF (88ºC)

Solution for error code Er:94

This Error Code will go away when the condition is remedied.
If Error happens again:


- Check if dip switch High Fire setting is ON. Switches 6 and 7 should be OFF for normal operation.
- Check exhaust temperature sensor. Ensure connections are secure.
- Check sensor resistance. If resistance is zero, replace the sensor.
- Check exhaust vent for blockage.
- If the problem persists, replace the control.
- If the problem persists, replace the heat exchanger. 


Share this page: Facebook Twitter





© 2025 ErrorHelp.us