ErrorHelp.us

Heating  Heating

Brand

HTP HTP List all brands

Type:

Mod con 1000 view Mod con 1000 List all types

Error code:

DHW
List all errors


Error code: DHW

Cause of error code DHW

This display indicates a temporary hold on the burner. There is a demand on the boiler from the DHW circuit for heat, the pump is powered on, but the boiler supply sensor indicates that the water temperature is too high to ignite. This is a temporary hold on the burner only and all other functions will remain functioning properly. This error will clear itself when either the boiler supply temperature drops below the BOILER SUPPLY minus boiler supply differential (5ºF) or DHW SETPOINT is satisfied and no longer calls for heat.

Solution for error code DHW