ErrorHelp.us

Heating  Heating

Brand

Laars Laars List all brands

Type:

Mascot MFTCW Wall-mounted view Mascot MFTCW Wall-mounted List all types

Error code:

Er:10
List all errors


Error code: Er:10

Cause of error code Er:10

Flame has extinguished 8 (Eight) times. 

Solution for error code Er:10

Press the Power button to clear the Error Code.
If Error happens again:
1. Monitor the gas pressure to the appliance while in operation. Ensure pressure is between 3.5 and 14” WC.
2. Check gas valve wire. Ensure connection is secure.
3. Check flame detection sensor. Ensure connections are secure. Normal operating settings are more than 2.5DC before ignition, less than 2.5DC after ignition.
4. Check vent terminations. Ensure there are no blockages.
5. Assure that the flame is stable when lit. 
6. If the problem persists, replace the main control.


Share this page: Facebook Twitter





© 2025 ErrorHelp.us