ErrorHelp.us

Heating  Heating

Brand

Lochinvar Lochinvar List all brands

Type:

Cadet CDN120 view Cadet CDN120 List all types

Error code:

E13
List all errors


Error code: E13

Cause of error code E13

The flue temperature has exceeded 250°F.

Solution for error code E13

- Inspect the heat exchanger.
- Inspect the flue sensor and associated wiring. Measure the resistance of the flue sensor. Replace the sensor if necessary.
- Verify that the vent/air intake pipes are properly installed and that there are no obstructions.
- Replace the main control board.


Share this page: Facebook Twitter