Cause of error code Air pressure SW

Air pressure switch contacts are open.

Solution for error code Air pressure SW

- Check the wiring connections to switch. Wires should be connected to the common and normally closed terminals.
- Air intake lengths exceed the maximum allowed lengths.
- Check for obstruction or blockage in the air intake pipes or at terminations.
- Check reference hoses connected to the air pressure switch for blockage or obstruction.
- Inspect the burner. Replace if necessary.
-  Inspect the heat exchanger. Replace if necessary.
- Faulty air pressure switch. Replace switch. 