Error code: E19

Cause of error code E19

Signal maximum return water temperature exceeded (T2>212°F).

Solution for error code E19

-Check actual return temperature. Increase of temperature cause by external heating source?


-Check return sensor NTC 2. Measure the resistance value  (see Appendix B)


-Exchange defective part if necessary. Change control unit when error persists