ErrorHelp.us

Heating  Heating

Brand

Rinnai Rinnai List all brands

Type:

Q205SN view Q205SN List all types

Error code:

bl85
List all errors


Error code: bl85

Cause of error code bl85

No water ? ow can be detected throughthe controller. De-aeration cycle is started. When water ? ow is detected during this cycle, the de-aeration cycle is terminated and the burner is released. The controller checks the water pressure during static and dynamic situation.

Solution for error code bl85

-Check the installation for the presence of air;If there is a secondary pump installed and it is not hydraulicly separated, it could cause pressure differences.
-Check the use of balancing valves



-check if the pump is functioning and/or that the water pressure sensor 

is working properly; Polluted pump; Polluted water pressure sensor; Polluted water ? lter; Wiring of pump.