ErrorHelp.us

Heating  Heating

Brand

U.S.Boiler Company U.S.Boiler Company List all brands

Type:

K2-120-02 view K2-120-02 List all types

Error code:

11
List all errors


Error code: 11

Cause of error code 11

Ignition failure



Models K2-080 through K2-180 - flame failure after 5 tries to restart.

-Flame rod not detecting flame.
-Condensate trap plugged.

Solution for error code 11

No gas pressure.
Gas pressure under minimum value shown on rating plate.
Gas line not completely purged of air.
Defective Electrode.
Loose burner ground connection.
Defective Ignition Cable.
Defective gas valve (check for 24 Vac at harness during trial for ignition       before replacing valve).
Air-fuel mixture out of adjustment - consult factory.
Defective or fouled electrode.
Plugged drain line in trap.


Share this page: Facebook Twitter