Error code: Err1

Cause of error code Err1

Temperature Sensor Fault

Solution for error code Err1

Temperature sensor failure, wire harness loose or shorted connection or control hardware failure:
-Check sensor is securely attached to boiler control
-Check that sensor wire is not damaged
-If secure and in good condition, replace sensor
-If problem persists, replace control