ErrorHelp.us

Heating  Heating

Brand

Westinghouse Westinghouse List all brands

Type:

WBRUNG080W view WBRUNG080W List all types

Error code:

Er:10
List all errors


Error code: Er:10

Cause of error code Er:10

Flame has Extinguished 8 (Eight) Times

Solution for error code Er:10

Press the Power button to clear the Error Code.
If Error happens again:
- Monitor the gas pressure to the boiler while in operation. Ensure pressure is between 3.5 and 14” WC.
- Check gas valve wire. Ensure connection is secure.
- Check flame detection sensor. Ensure connections are secure. Normal operating settings are more than 2.5DC before ignition, less than 2.5DC after ignition.
- Check vent terminations. Ensure there are no blockages.
- Assure that the flame is stable when lit.
- If the problem persists, replace the main control. 