Error code: F14

Cause of error code F14

The data received from the tank sensors exceeds the difference allowed by the control.

Solution for error code F14

- Manually reset the water heater.
- Observe water heater operation. If fault code occurs again:
- Check the Dual Temperature Sensor. Ensure it is properly wired to the control, and that there are no breaks, cuts, or other visible issues with the sensor wire.
- Use an ohmmeter to check resistance on first Sensor A, then Sensor B of the Dual Temperature Sensor.
- Replace Dual Temperature Sensor if either Sensor A or Sensor B fails the resistance test.