ErrorHelp.us

Heating  Heating

Brand

Westinghouse Westinghouse List all brands

Type:

WGRTNG199 view WGRTNG199 List all types

Error code:

Er:16
List all errors


Error code: Er:16

Cause of error code Er:16

Operating Temperature Sensor or DHW Sensor detects Water Temperature Greater than 199oF (93oC). 

Solution for error code Er:16

This Error Code will go away when the DHW temperature decreases.
If Error happens again:
- Check if dip switch High Fire setting is ON. Switches 6 and 7 should be OFF for normal operation.
- Check if DHW pipe is blocked. Ensure there is enough water flowing to the water heater.
- Check DHW sensor at DHW outlet. If resistance is zero, replace the sensor.
- Check Operating Temperature sensor at the heat exchanger. If resistance is zero, replace the sensor.
- If the problem persists, replace the main control.


Share this page: Facebook Twitter





© 2025 ErrorHelp.us