ErrorHelp.us

Heating  Heating

Brand

Wiliamson Wiliamson List all brands

Type:

FS-80LPFS-80LP
List all types

Error code:

FAULT 52 =
List all errors


Error code: FAULT 52 =

Cause of error code FAULT 52 =

Too high difference between two CH supply water temperature sensors.

Solution for error code FAULT 52 =

When the system measures a difference between two CH supply water temperature sensors equal or higher than 18ºF ( with a confirming time of 10 seconds), error 52 is created. This error condition is stopping the boiler and to get to the normal operation again, the temperature between the two CH supply water temperature sensors has to be lower than 14°F for 10 seconds. When this timer is expired, error will be resolved.


Share this page: Facebook Twitter